Always keep the implement clean. Do
not use cleaning agents or solvents.
We cannot be held liable for damage
caused by our implements if they were
improperly repaired, if non-original parts
have been used or if they were used not in
keeping with their intended purpose.
Exchanging the cylinder
Switch off the implement, disconnect
the mains plug and wait until the
cylinder is standing still.
Wear gloves when handling the cyl-
inder.
E
1. Turn the implement over.
2. Take the spanner (
A
13) out of
the holder (
A
14).
3. Loosen the fastening screws and
pull the bearing support up-
wards.
4. Tilt the cylinder (
A
20/21) up-
wards and pull the shaft out of
the square receptacle (24).
F
5. Insert the new cylinder (
A
20/21) by reversing the se-
quence.
Storage
Store the implement in a dry place well
out of reach of children.
Allow the motor to cool down before
placing the implement in a closed
room.
Do not wrap nylon sacks around the
implement as this could result in the for-
mation of moisture.
G
Loosen the wing nuts so that the bar
can be folded up for space-saving
storage.
Ensure that the cables are not
squeezed.
Disposal and protection
of the environment
Dispose of the implement, accessories and
packaging in an environment-friendly man-
ner.
Electrically-powered appliances
must not be disposed of with the
domestic waste.
Hand in the spent implement to a recycling
centre. The plastic and metal parts can then
be sorted out and graded for recycling.
Our Service Center will be happy to an-
swer any questions in this respect.
Page view 61