Page view 46
47
GB
Working
Supervise the appliance while it is
in operation in order to be immedi-
ately aware if the automatic cut-out
operates or the pump runs dry, to
limit any damage to a minimum.
In automatic mode, the oat switch auto-
matically switches the pump on or off.
Adjustingtheoatswitch:
The on/off switch point on the oat switch
(
6) can be adjusted by changing the
position of the oat switch in the oat
switch grid (
8).
In the case of stationary installation,
check regularly (no less then once
every three months) that the oat
switch (
6) is working.
Checktheoatswitch( 6):
- It must be positioned so that it
can lift and lower freely. The
switching point heights “On”
and “Off” must be easy to
reach.
Check this by placing the pump
into a vessel lled with water
and lift the oat switch (6) care-
fully by hand and then lower it
again. In this case, you can see
whether the pump switches on
and off.
- Ensure that the distance between
the oat switch and the oat switch
grid (
8) is not too small.
- During the adjustment of the oat
switch (6), ensure that the oat
switch does not contact the oor
before the pump switches off.
The pump will run dry if too long a
oat switch cable (
7) is chosen.
Maintenance and
Cleaning
Clean and maintain your equipment regu-
larly. This will guarantee its performance
and long durability.
Ask our service centre to car-
ry out any work that is not
described in these instruc-
tions. Use only original parts.
There is a risk of injury!
Pull out the power plug before eve-
ry maintenance operation. There is
a risk of electrocution or of injury
from moving parts.
General cleaning instructions
In case of transport for utilization in
different locations, the pump must be
cleaned with clear water after every use.
In case of stationary installation, the
function of the oat switch (
6) is
to be checked regularly (at the latest
every three months).
With a water jet, remove uff and
brous particles which are possibly
present in the pump casing (
3).
Clean precipitation from the oat
switch (
6) with clear water.
Regularly remove sludge from the pit
base (at the latest every 3 months) and
also clean the shaft walls
Page view 46